The water intake valve is not fully open.
Open the water intake valve fully and start operation again.
Fault F13 is shown on the display of the steam oven/combination steam oven. The temperature in the oven compartment is too high.
Open the water intake valve fully and start operation again.
The water nozzle must be descaled if the fault message F13 appears on the display.
To descale the nozzle, proceed as follows:
Wait until several buzzer tones sound.
Open the door and remove the food.
Leave the door open to cool down the steam oven.
Remove the side runners.
Pull out the nozzle.
Descale the nozzle using the Miele system descaling agent or with a suitable proprietary descaler.
After descaling, rinse the nozzle under running water.
Before replacing the nozzle, all parts of the steam oven which carry water must be flushed through.
Close the door and switch the steam oven on. Select the Steam cooking operating mode at 100 °C.
Set a duration of 1 minute and press the Start/Stop button.
Wait until the cooling down phase has been completed, then open the door and replace the nozzle and the side runners.
The steam oven can now be used again as normal.
If the fault persists, please contact us or book a repair appointment online.